mirror of
https://github.com/AvengeMedia/DankMaterialShell.git
synced 2025-12-05 21:15:38 -05:00
brightness: more aggressive ddc rescans on device changes
This commit is contained in:
@@ -40,6 +40,10 @@ func (b *DDCBackend) scanI2CDevices() error {
|
||||
return b.scanI2CDevicesInternal(false)
|
||||
}
|
||||
|
||||
func (b *DDCBackend) ForceRescan() error {
|
||||
return b.scanI2CDevicesInternal(true)
|
||||
}
|
||||
|
||||
func (b *DDCBackend) scanI2CDevicesInternal(force bool) error {
|
||||
b.scanMutex.Lock()
|
||||
defer b.scanMutex.Unlock()
|
||||
@@ -261,8 +265,16 @@ func (b *DDCBackend) setBrightnessImmediateWithExponent(id string, value int) er
|
||||
|
||||
busPath := fmt.Sprintf("/dev/i2c-%d", dev.bus)
|
||||
|
||||
if _, err := os.Stat(busPath); os.IsNotExist(err) {
|
||||
b.devices.Delete(id)
|
||||
log.Debugf("removed stale DDC device %s (bus no longer exists)", id)
|
||||
return fmt.Errorf("device disconnected: %s", id)
|
||||
}
|
||||
|
||||
fd, err := syscall.Open(busPath, syscall.O_RDWR, 0)
|
||||
if err != nil {
|
||||
b.devices.Delete(id)
|
||||
log.Debugf("removed DDC device %s (open failed: %v)", id, err)
|
||||
return fmt.Errorf("open i2c device: %w", err)
|
||||
}
|
||||
defer syscall.Close(fd)
|
||||
|
||||
@@ -89,6 +89,13 @@ func (m *Manager) initDDC() {
|
||||
|
||||
func (m *Manager) Rescan() {
|
||||
log.Debug("Rescanning brightness devices...")
|
||||
|
||||
if m.ddcReady && m.ddcBackend != nil {
|
||||
if err := m.ddcBackend.ForceRescan(); err != nil {
|
||||
log.Debugf("DDC force rescan failed: %v", err)
|
||||
}
|
||||
}
|
||||
|
||||
m.updateState()
|
||||
}
|
||||
|
||||
|
||||
@@ -5,13 +5,18 @@ import (
|
||||
"path/filepath"
|
||||
"strconv"
|
||||
"strings"
|
||||
"sync"
|
||||
"time"
|
||||
|
||||
"github.com/AvengeMedia/DankMaterialShell/core/internal/log"
|
||||
"github.com/pilebones/go-udev/netlink"
|
||||
)
|
||||
|
||||
type UdevMonitor struct {
|
||||
stop chan struct{}
|
||||
stop chan struct{}
|
||||
rescanMutex sync.Mutex
|
||||
rescanTimer *time.Timer
|
||||
rescanPending bool
|
||||
}
|
||||
|
||||
func NewUdevMonitor(manager *Manager) *UdevMonitor {
|
||||
@@ -34,10 +39,8 @@ func (m *UdevMonitor) run(manager *Manager) {
|
||||
matcher := &netlink.RuleDefinitions{
|
||||
Rules: []netlink.RuleDefinition{
|
||||
{Env: map[string]string{"SUBSYSTEM": "backlight"}},
|
||||
// ! TODO: most drivers dont emit this for leds?
|
||||
// ! inotify brightness_hw_changed works, but thn some devices dont do that...
|
||||
// ! So for now the GUI just shows OSDs for leds, without reflecting actual HW value
|
||||
// {Env: map[string]string{"SUBSYSTEM": "leds"}},
|
||||
{Env: map[string]string{"SUBSYSTEM": "drm"}},
|
||||
{Env: map[string]string{"SUBSYSTEM": "i2c"}},
|
||||
},
|
||||
}
|
||||
if err := matcher.Compile(); err != nil {
|
||||
@@ -49,7 +52,7 @@ func (m *UdevMonitor) run(manager *Manager) {
|
||||
errs := make(chan error)
|
||||
conn.Monitor(events, errs, matcher)
|
||||
|
||||
log.Info("Udev monitor started for backlight/leds events")
|
||||
log.Info("Udev monitor started for backlight/drm/i2c events")
|
||||
|
||||
for {
|
||||
select {
|
||||
@@ -75,11 +78,54 @@ func (m *UdevMonitor) handleEvent(manager *Manager, event netlink.UEvent) {
|
||||
sysname := filepath.Base(devpath)
|
||||
action := string(event.Action)
|
||||
|
||||
switch subsystem {
|
||||
case "drm", "i2c":
|
||||
m.handleDisplayEvent(manager, action, subsystem, sysname)
|
||||
case "backlight":
|
||||
m.handleBacklightEvent(manager, action, sysname)
|
||||
}
|
||||
}
|
||||
|
||||
func (m *UdevMonitor) handleDisplayEvent(manager *Manager, action, subsystem, sysname string) {
|
||||
switch action {
|
||||
case "add", "remove", "change":
|
||||
log.Debugf("Udev %s event: %s:%s - queueing DDC rescan", action, subsystem, sysname)
|
||||
m.debouncedRescan(manager)
|
||||
}
|
||||
}
|
||||
|
||||
func (m *UdevMonitor) debouncedRescan(manager *Manager) {
|
||||
m.rescanMutex.Lock()
|
||||
defer m.rescanMutex.Unlock()
|
||||
|
||||
m.rescanPending = true
|
||||
|
||||
if m.rescanTimer != nil {
|
||||
m.rescanTimer.Reset(2 * time.Second)
|
||||
return
|
||||
}
|
||||
|
||||
m.rescanTimer = time.AfterFunc(2*time.Second, func() {
|
||||
m.rescanMutex.Lock()
|
||||
pending := m.rescanPending
|
||||
m.rescanPending = false
|
||||
m.rescanMutex.Unlock()
|
||||
|
||||
if !pending {
|
||||
return
|
||||
}
|
||||
|
||||
log.Debug("Executing debounced DDC rescan")
|
||||
manager.Rescan()
|
||||
})
|
||||
}
|
||||
|
||||
func (m *UdevMonitor) handleBacklightEvent(manager *Manager, action, sysname string) {
|
||||
switch action {
|
||||
case "change":
|
||||
m.handleChange(manager, subsystem, sysname)
|
||||
m.handleChange(manager, "backlight", sysname)
|
||||
case "add", "remove":
|
||||
log.Debugf("Udev %s event: %s:%s - triggering rescan", action, subsystem, sysname)
|
||||
log.Debugf("Udev %s event: backlight:%s - triggering rescan", action, sysname)
|
||||
manager.Rescan()
|
||||
}
|
||||
}
|
||||
|
||||
@@ -752,15 +752,28 @@ Singleton {
|
||||
|
||||
Timer {
|
||||
id: screenChangeRescanTimer
|
||||
property int rescanAttempt: 0
|
||||
interval: 3000
|
||||
repeat: false
|
||||
onTriggered: rescanDevices()
|
||||
onTriggered: {
|
||||
rescanDevices();
|
||||
rescanAttempt++;
|
||||
if (rescanAttempt < 3) {
|
||||
interval = rescanAttempt === 1 ? 5000 : 8000;
|
||||
restart();
|
||||
} else {
|
||||
rescanAttempt = 0;
|
||||
interval = 3000;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
Connections {
|
||||
target: Quickshell
|
||||
|
||||
function onScreensChanged() {
|
||||
screenChangeRescanTimer.rescanAttempt = 0;
|
||||
screenChangeRescanTimer.interval = 3000;
|
||||
screenChangeRescanTimer.restart();
|
||||
}
|
||||
}
|
||||
|
||||
Reference in New Issue
Block a user